Command Manual – Integrated Management
Quidway S8500 Series Routing Switches
Parameter
port-list: List of ports to be set.
uprate-list: The uplink rate to be configured, ranging from 1.5 to 12.5. The number of
uplink rate values must be consistent with the number of ports.
downrate-list: The downlink rate to be configured, ranging from 4 to 12.5. The number
of downlink rates must be consistent with the number of ports.
Description
Use the set vdsllink command to set the VDSL link rate of the port of the switch.
Example
# Set the VDSL link uplink rate and downlink rate of the port 1 of the Ethernet switch
with the position parameter of "8/1/1-/" to 2 and 2.
[Quidway-lanswitch8/1/1-/] set vdsllink 1 uprate 2 downrate 2
Waiting.....
Config VDSL link successfully!
Note:
This command is only applicable to configuration of S3026 Ethernet switch on the
NMS.

1.3.39 set vlanid

Syntax
set vlanid vlanid port-list
undo set vlanid vlanlist
View
lanswitch view
Parameter
vlanid: VLAN ID.
port-list: List of ports.
vlanlist : List of VLAN IDs.