The channels for filtering in all the directions are specified by this configuration
command. All the information will be sent to the corresponding directions through the
specified channels. You can configure the channels in the output direction, channel
filter information, filtering and redirecting of all kinds of information.
At present, the system distributes an information channel in each output direction by
default, shown as follows:
Table 4-13 Default information channel in each output direction
Console
Monitor
Info-center loghost
Log buffer
Trap buffer
snmp
Log file
In addition, each information channel has a default record with the module name
"default" and module number as 0xffff0000. However, for different information channel,
the default log, trap and debugging settings in the records may be different with one
another. Use default configuration record if a module does not have any specific
configuration record in the channel.
Example
# Configure to enable the log information of VLAN module in SNMP channel and allows
the output of the information with a level higher than emergencies.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] info-center source vlan channel snmp log level emergencies

4.6.16 info-center timestamp

Syntax
info-center timestamp { log | trap | debugging } { boot | date | none }
undo info-center timestamp { log | trap | debugging }
View
System view
Output direction
Huawei Technologies Proprietary
4-52
Chapter 4 System Maintenance Commands
Information channel name
console
monitor
loghost
logbuffer
trapbuffer
snmpagent
logfile