If you repeatedly use this command, the latest configuration overwrites the previous
one.
You can remove a TACACS scheme authorization server only when no Active TCP
connection used to send authorization packets is now using the server, and the removal
impacts only packets forwarded afterwards.
Related command: display hwtacacs.
Example
# Configure the secondary authorization server.
[Quidway] hwtacacs scheme test1
[Quidway-hwtacacs-test1] secondary authorization 10.163.155.13 49

2.3.18 timer quiet

Syntax
timer quiet minutes
undo timer quiet
View
HWTACACS view
Parameter
minutes: Ranges from 1 to 255 minutes. By default, the primary server must wait five
minutes before it resumes the active state.
Description
Use the timer quiet command to set the waiting time before the primary server
resumes the active state.
Use the undo timer quiet command to restore the default configuration.
This command is designed to inhibit the switch from processing user request packets
for a time when the communication between the switch and the server is interrupted.
After the switch waits for a time that is equal or greater than the time set by this
command, it re-attempts to send packets to the server.
Related command: display hwtacac.
Example
# Set the quiet timer for the primary server to ten minutes.
[Quidway] hwtacacs scheme test1
[Quidway-hwtacacs-test1] timer quiet
Chapter 2 AAA and RADIUS/HWTACACS Protocol