Credential readers
An input device with either Wiegand (Data1/Data0) or Magnetic (Clock and Data) bit stream
can be used with the CT5000. The CT5000 provides two (2) separate credential reader
interfaces for control of one (1) opening.
The following readers are UL294 listed for use with the CT5000:
Essex Electronics model KTP-162
Mercury Security models MR-5 and MR-20, and XceedID models XF-1050, XF-1100,
XF-1500, XF-1550 and XF-2100
The following readers are ULCS319 listed for use with the CT5000:
XceedID models PR10, SM10, MT11, MT11-485, MT15, MT15-485, MTK15 and MTK15-485.
Connect the shield of the reader 1 cable to the CT5000 J17-3 terminal (GND). Connect the
shield of the reader 2 cable to the CT5000 J18-3 terminal (GND). Do not connect the cable
shield at the credential reader.
Reader input ports are designed for 5V logic. Any voltage greater than 5V may
L
cause damage to either the CT5000 or the reader(s).
The CT5000 does not provide power to the reader(s). Power must be provided to the
reader(s) separately by a UL listed power supply. Refer to Wiring Diagram examples
on page 10, page 11, and page 12.
The CT5000 may not provide complete control of the reader's beeper or LEDs. Please
consult the reader's manufacturer for instruction on reader configuration.
Make sure your reader is configured with the LEDs and beeper OFF for best
compatibility.
Reader 1
terminal
CLK/D1
J17-1
DATA/D0
J17-2
GND
J17-3
BEEPER
J17-4
GRN
J17-5
RED
J17-6
Reader 2
terminal
Credential reader inputs: Each input line is pulled to
J18-1
GND through a 12V transient suppressor and a 2 mega-
ohm resistor.
J18-2
Wiegand or magnetic format is automatically detected.
The signal ground of the CT5000 must be tied to the
J18-3
signal ground at the reader.
Beeper signal line connection to the reader.
This is an "open collector" style output, and has a 12V
transient suppressor to GND.
J18-4
The output is switched to GND through a 100 ohm
resistor to activate the beeper on the reader.
Note: Most readers beep independently, and beeper
performance depends on the specific reader model.
Green LED signal line connection to the reader.
This is an "open collector" style output, and has a 12V
J18-5
transient suppressor to GND.
The output is switched to GND through a 100 ohm
resistor to activate the green LED on the reader.
J18-6
Red LED signal line connection to the reader.
This is an "Open Collector" style output, and has a 12V
transient suppressor to GND.
The output is switched to GND through a 100 Ohm
resistor to activate the red LED on the reader.