Appendix B - Board Configuration Differences
Appendix B
Noted Board Configuration Differences
Memory Reset
42
Because of Schlage Biometrics' camera retrofit of the HandPunch some changes have
been made to the main PCB and they are listed as follows:
• Dipswitches have been removed
- memory is reset with a push-button reset and user interface with keypad and LCD
• Power has moved to the right side of the PCB
• The RS-232 RJ-45 receptacle has been replaced with a 4 pin Molex connector on the
left side of the PCB
• A 2 pin Molex connector (J5) has been added to the board, next to the reset button,
to supply power for the LEDs. This connector should never be unplugged. unless a
modem or Ethernet is added to the PCB
• The upgrading of the memory is now handled through software codes at the
HandPunch. Contact Order Entry for memory upgrades
To reset the memory of the HandPunch follow these steps-
1. Remove power and battery jumper, if a back up battery is installed
2. Press down on reset button and apply power
3. Release button
4. Reader will boot to
• Press 1 to erase setup i.e. address, outputs, passwords, but retain user database and
datalogs
• Press 9 to erase everything i.e. HandPunch goes back to factory defaults
ERASE
:1 SETUP
:9 ALL!!!