Hang Terminal and Run Wires
3. There are several options for
running the wiring a. Run
wiring through hole in wall
plate.
a. Run wiring through hole
in wall plate.
b. Run wiring through slot in
terminal.
c. Run wiring through
battery cover (material
removal required).
If using option c, locate
indentation in battery cover,
drill 1/4" hole in battery cover
indentation and use utility
knife to remove excess
material.
4. Tuck wires under tabs on
terminal to minimize risk of
crimping wires.
5. Follow all local electrical codes
when routing wire and making
the terminal connections.
For concealed wiring, pull the
terminal wiring through the 1\2"
cable entry hole.
Ensure there is at least twelve
inches of extra cable beyond what
is needed to make the required
connections to the back board.
For conduit wiring, pull an extra
twelve inches of cable through the
conduit beyond what is needed to
make the required connections to
the back board.
You may need to run the cable
and then attach the connectors in
order to fit cables through necessary
holes and/or slots.
30 - GT-Series Terminal User's Guide
Remove shaded
material if using
option c.
c
(two possible
locations)
Figure 3.12— Terminal Wiring Options
Tabs
Figure 3.13— Wire Tabs
a
b