Connector
J2
J10/J11
(1)
J10/J11
(2)
J10 for
Access
J10/J11
Point A
(3)
J11 for
Access
Point B
J10/J11
(4)
J10/J11
(5)
J10/J11
(6)
10 • Schlage • PIM400-TD2 user guide
ACCESS CONTROL PANEL CONNECTIONS
PIM400-TD2
signal
12V+
12 or 24 VDC
Request to Enter
input signal
REQ TO
ENTER
Request to Enter
common contact
(GND)
General purpose
alarm input signal
TROUBLE
General purpose
alarm common
contact (GND)
Door Status input
signal
DOOR 1/2
STATUS
Door Status input
common contact
(GND)
ACP signal
PIM400-TD2 inputs for 12 or 24
VDC power.
Draws 250mA max.
If the Access Control Panel
(ACP) reader power outputs do
not source enough current for
the PIM400-TD2, use the ACP
main regulated 12 VDC power
supply or a separate UL294 or
ULCS318/ULCS319 listed 12 or
24 VDC power supply.
Power input is non polarized.
PIM400-TD2 output indicating
when the access point exterior
door handle is making a request
to enter.
Connect to the ACP request to
enter input.
Connect only if the access point
needs to have Request to Enter
function.
The request to enter signal
polarity may be configured using
the sus. This setting is shared
with the request to exit signal.
Output is pulled-up to 5 VDC and
can sink 50mA.
PIM400-TD2 output indicating
trouble is reported by the access
point.
Logic polarity is configurable
using the SUS.
Output is pulled-up to 5 VDC and
can sink 50mA.
PIM400-TD2 output indicates
the position of the access point
portal, open or closed.
Connect only if the ACP needs
to know the access point portal
state.
Logic polarity is configurable
using the SUS.
Output is pulled-up to 3.6 VDC
and can sink 50mA.
Description/Explanation