Schlage PIB300 User Manual page 969

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Smart Card Tab
Table 11.3: DESFire Definition Fields
Field
Req'd?
DESFire definition
Yes
name
Biometric template
Yes
compression
DESFire
Yes
communication
Enter "new" user
Yes
file key
Enter "new"
Yes
application master
key
Enter "new" PICC
Yes
master key
Enter "old" user file
Yes
key
Enter "old"
Yes
application master
key
Enter "old" PICC
Yes
master key
Change automatic
Yes
user file key update
Table 11.4: DESFire Card Compression
No Compression
Minimum Compression
Medium Compression
Maximum Compression
40 • Schlage • HandNet Lite Terminal User's Guide
Description
• Name of the DESFire definition
• Any name that distinguishes this definition from others
• Controls the amount of compression of the finger template before it is written to the DESFire
card
• Maximum compression should be used initially
• See
Table 11.4: DESFire Card Compression
• Select either Plain Text or DESFire ciphered
• Check the box to edit these fields.
• Key entered must be exactly the same in both boxes.
• Check the box to edit these fields.
• Key entered must be exactly the same in both boxes.
• Check the box to edit these fields.
• Key entered must be exactly the same in both boxes.
• Check the box to edit these fields.
• Key entered must be exactly the same in both boxes.
• Check the box to edit these fields.
• Key entered must be exactly the same in both boxes.
• Check the box to edit these fields.
• Key entered must be exactly the same in both boxes.
• The automatic user key update choices are:
• Do not change
• Disable auto key update
• Start unlimited auto key update
• Start limited auto key update (displays two additional fields)
• With limited auto key update the operator can select the number of cards to be updated and/
or the number of cards to automatically update.
Number of Enrolled Fingers
1
854 bytes
566
454
310
on page
2
1654 bytes
1078
854
566
40
for more information.