Lock Functions; Schlage Utility Software (Sus) - Schlage PIB300 User Manual

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

The AD-250 is available in one of four functions:
Privacy (40): Lockset is normally secure. Pressing the Inside Push Button or extending the
deadbolt will disable normal electronic access from the outside. Opening the door, retracting
the deadbolt or pressing the Inside Push Button a second time deactivates the privacy
status.
Office (50): Lockset is normally secure. Inside Push Button may be used to select passage
or secured status.
Apartment (60): Lockset is normally secure. Inside Push Button is used to select passage or
secure status. While in the secure state, opening the door or pressing the Inside Push Button
causes the lockset to toggle unsecured. The door must be closed and a valid credential
presented to secure the lockset from the outside.
Classroom/Storeroom (70): Lockset is normally secure. Valid toggle credentials may be
used to change to a passage or secure status.
Follow these steps when setting up a new lock.
1. Install the lock. See the installation guide that came with the lock, or visit
www.allegion.com/us (see Support>Schlage Electronics>Electronic Locks Technical
Library) for more information.
2. Make sure the batteries are installed properly. See Batteries on page 8 for more
information.
3. Configure the master construction credential (where applicable). See Construction
access mode on page 5 for more information. The lock will remain in construction
access mode until you are ready to set up the rest of the system.
4. Test the lock for proper mechanical and electronic operation. See Test lock operation on
page 6 for more information.
5. Consult the Schlage Utility Software (SUS) user guide for information about configuring
the lock.
6. Familiarize yourself with the information contained in this user guide.
Save this user guide for future reference.
The Schlage Utility Software is used for programming and setup only.
The Schlage Utility Software (SUS) is used to configure locks. This includes transferring
data files between the access control software and locks. For further information about
SUS, see the SUS user guide.
4 • Schlage • AD-250 user guide

Lock functions

Getting started

Schlage Utility Software (SUS)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pib301

Table of Contents