P516-097 PIB300 USER GUIDE INSTALLATION AND OPERATION INSTRUCTIONS FOR PANEL INTERFACE BOARD Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française, veuillez consulter le site www.schlage.com/support...
PIB300 Installation......................... 4 Location ............................. 4 Wiring to the Lock ........................4 Connecting the PIB300 to the Access Control Panel (ACP)............5 Cable/Wire Specifi cations ......................5 Typical Wiring to the Access Control Panel ................5 PIB300 to ACP Connection ......................6 Completing Installation ........................
• Provides two-way communication with locks via a RS-485 connection • Up to two Schlage AD-300 locks or up to two RS-485 based legacy locks communicating with the RSI or VIP protocol may connect to an Access Control Panel (ACP) or reader interface board.
• Wiring of locks requires one connector via the RS-485 connector (J5). • Connections from lock to lock should be daisy-chained (see diagram below). • The power supply is located at or near the PIB300 for short wire runs, or local to locks if located far from the panel.
12 to 24 VDC. Refer to Typical Wiring to the Access Control Panel below for how to connect DC power to the PIB300. Use shielded cables for the signal wiring between the PIB300 and the Access Control Panel. For maximum wire lengths and cable specifi cations, see Cable/Wire Specifi cations below.
PIB300 TO ACP CONNECTION ACCESS CONTROL PANEL CONNECTION Connector PIB300 Signal Access Panel Signal Description/Explanation PIB300 inputs for 12 to 24 VDC power. If the Access Control Panel (ACP) reader power outputs do not source enough current for 12V+ 12 to 24 VDC...
Page 7
Connect only if the access point needs to be unlocked (door) or raised (gate). J8 for J8/J7 (3) D1/CLK Clock or Data 1 Output PIB300 outputs used to present Access card data to the Access Control Point A Panel (ACP). J7 for...
1. Remove the main cover. 2. Press and hold both link buttons for over 3 seconds. 3. Release both link buttons. The PIB300 will blink the red lights beside each link button while confi guration reset takes place. 4. The two green lights beside the link buttons will blink 3 times when the reset is complete.