Configuration Tab
Table 10.6: Fingerprint Settings Fields
Field
Req'd?
iCLASS
Yes
Configuration
Mifare standard
Yes
Configuration
DESFire
Yes
Configuration
Input Format 1-5
Yes
Output Format
Yes
Keypad Format
Yes
Action on ID
Yes
Overflow
Action on ID
Yes
Unknown
Action on
Yes
Biometric Reject
Action on Duress Yes
Value
Yes
30 • Schlage • HandNet Lite Terminal User's Guide
Description
• Choose None unless you are using iCLASS readers and cards.
• If using iCLASS readers and cards, choose any iCLASS configuration that you've defined.
• See
Add an iCLASS Definition
• Choose None unless you are using Mifare Standard readers and cards.
• If using Mifare Standard readers and cards, choose any Mifare Standard definition that you've
defined.
• See Add a Mifare Standard Definition on page 57 for more information.
• Choose None unless you are using Mifare DESFire readers and cards.
• If using Mifare DESFire readers and cards, choose any Mifare DESFire definition that you've
defined.
• See
Add a DESFire Definition
• Card formats reader will accept from an internal or external card reader.
• Choose either Wiegand or Magstripe formats but not both. Most companies use only one
format. See
Table 10.7: Card Format Fields
• If you change from Wiegand to Magstripe format, or from Magstripe to Wiegand, you must
reboot the reader. See the reader manual for further detail
• Format reader sends to the access control panel if you use an internal or external card reader.
• Use Input Format: Passes through whatever format is received
• None: Reader sends no output when the ID is entered with a card.
• Formats 1-11: Choose one of the formats from
• Format the reader sends to the access control panel when a user enters his ID on the keypad
instead of using a card.
• None: Reader sends no output when the ID is entered with the keypad.
• Formats 1-11: Choose one of the formats from
• Indicates what reader sends to access panel when card ID is longer than maximum length
permitted by selected formats.
• Suppress Output: Reader sends no output
• Substitute all 1 bits: All 1 (one) bits are sent instead of the ID that was entered
• Substitute all 0 bits: All 0 (zero) bits are sent instead of the ID that was entered
• Controls what the reader sends the access panel when ID is not recognized
• Suppress Output: reader sends no output
• Alternate Facility Code Value: reader sends facility code entered in the value entry, instead of
the normal facility code
• Increment/Decrement Facility Code Value: Reader sends facility code increased or decreased
by the amount in the Value entry.
• Toggle All Parity Bits: reader toggles the output parity bits.
• Controls what the reader sends the access panel when a valid ID is entered but the finger
doesn't match the template.
• Same four options here as for Action on ID Unknown
• Controls what the reader sends the access panel when a user places a duress finger
• Same four options here as for Action on ID Unknown
• Number between 0 and 32767
• Used when either Alternate Facility Code Value, Increment/Decrement Facility Code Value is
chosen in the previous three fields
• Enter a minus (-) sign before the number if you want to decrement the value.
on page
35
for more information.
on page
39
for more information.
on page
32
for more information.
Table 10.7: Card Format Fields
Table 10.7: Card Format Fields