Schlage PIB300 User Manual page 1201

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

menus are setting up the reader's address and communication settings
during initial setup, recalibrating the reader, and enrolling users at the
reader if you are not using the Enroll option on the Reader menu.
Lock Output OFF: Someone chose Relock from the Reader menu to relock an
unlocked door; see page 128 for more about locking and unlocking doors.
Lock Output ON: Someone chose to unlock a door using one of the Unlock
options on the Reader menu; see page 128 for more about locking and
unlocking doors.
Lock Setup Changed: Using the command menus in the reader, someone
changed the number of seconds the lock should be unlocked for or
the number of seconds the door is allowed to be open (normally this is
changed in HandNet on the Configuration tab in Reader Properties; if it is
changed there, you just see the message Reader Properties Changed).
Manual Import Started: The operator selected Import Users to import users
from the import.mdb file; see page 99 for more about importing users
(when you must import users manually or whether HandNet imports them
automatically is controlled by the Enable box under Auto Import on the
User Import/Export tab in System Settings; see page 28).
Maximum ID Length Changed: Someone changed the maximum length for
a user ID using the command menus in the reader (if you changed the ID
length on the Settings tab in the Reader Properties, you would just see the
message Reader Properties Changed).
Memory Cleared: Someone used the Clear Memory option from the Command
menus in the reader. This erases all the users from the reader (typically
you would do this if you were changing the use of the reader and wanted
to make sure that those who previously had access through this reader no
longer had access through it).
Messages Read: You should not see this message.
No Hand Read For Card: You should not see this message.
Operating Mode Changed: The operating mode of the reader has been
changed using the command menus in the reader.
Operator Added: A new operator (someone authorized to use HandNet) was
added on the Operators tab in System Settings; see page 24 for more
about adding operators.
Operator Deleted: An operator (someone authorized to use HandNet) was
removed from the Operators tab in System Settings; see page 24 for more
about deleting operators.
Operator Login: An operator logged into HandNet.
Operator Logout: An operator logged out of HandNet.
Operator Properties Changed: Someone changed the tasks that an operator
is allowed to do on the Operators tab in System Settings; see page 24 for
more about controlling which options an operator can use.
HandNet for Windows
119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pib301

Table of Contents