Smart Card Tab
As you use either Automatic or Manual sector assignment the display in the Mifare sector assignments group will change showing
you the current assignment.
If your installation is currently using Mifare Standard cards with another device and you wish to add FingerKey biometrics to your
existing cards you will wish to:
a.
Determine if your current cards are formatted to use a Mifare Application Directory. Contact your existing device
manufacturer. You can attempt to use the "Read card sectors" button in HandNet lite to attempt to read an existing MAD
on the card.
b.
If your current cards are not formatted to use a MAD, then you will need to determine which sectors your current device
manufacturer uses on your card. It is normal that sector 0 will be used, but your current cards may also contain data in
additional sectors. Check with your existing device manufacturer to determine which sectors on your cards are available
and begin the Schlage Biometrics sector assignment at the first free sector.
Once you are satisfied with the card definition, click the "Accept settings" button to record the definition. You will then need to
go back to the "Configuration" tab, and for each FingerKey to use this Mifare Standard definition you will need to "Edit selected
reader", click "Fingerprint settings" and use the drop down for "Mifare standard configuration" and select the saved Mifare Standard
Definition.
It is important that each FingerKey be assigned the correct Mifare standard configuration setting.
Table 11.7: Mifare Card Compression
No Compression
Minimum Compression
Medium Compression
Maximum Compression
Number of Enrolled Fingers
1
854 bytes
566
454
310
2
1654 bytes
1078
854
566
Schlage • HandNet Lite Terminal User's Guide • 43