Other Ongoing Activities; Reader Maintenance; Cleaning Readers; Recalibrating Readers - Schlage PIB300 User Manual

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Other Ongoing Activities

Reader Maintenance

Cleaning
Readers
Recalibrating
Readers
124
You should periodically clean hand readers; if you do not, users may get
rejected more often.
Spray any ordinary, non-abrasive cleaner on a clean cloth, and then use the
cloth to wipe the platen, the mirror and reflector on the sides of reader, and the
window above the platen. When wiping the platen, start from the back corners
and wipe forward.
Never spray cleaning fluid directly onto the reader! Always spray a cloth and
then wipe the reader with the cloth.
Never use an abrasive or gritty cleaner! An abrasive cleaner could scratch
the reader; this would damage it.
If users are often being rejected at a particular reader, try recalibrating it. To do
this:
1. Check the list of users to make sure you have an authority level of one or
higher. If you have an authority level of None, you cannot do this (to change
your authority level, double-click your name on the list of users, click the
Security tab, click the Authority Level entry, and select the appropriate level).
2. Go to the reader to be recalibrated, and enter command mode on the
reader:
If you have a HandKey II or HandKey CR reader: Press CLEAR, and
then press ENTER.
If you have an ID3D HandKey reader: Press # AND * (you can press
them at the same time, or one after the other).
The display on the reader should look like this:
3. Type your User ID number (the same one you enter to get access through
the reader), and press ENTER or #. The reader asks you to place your
READY
* :
ENTER PASSWORD