Reset To Factory Defaults; Level 1 Factory Default Reset; Level 2 Factory Default Reset - Schlage PIB300 User Manual

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Test the AD-250 in construction access mode
1. When the master construction credential is presented, the lock will beep and the
Schlage button will light green for 20 seconds awaiting the presentation of another
credential to be granted construction user access.
2. When a valid construction access user credential is presented, the lock will unlock for the
re-latch delay period (default three seconds), and the Schlage button will blink green.
When the lock re-locks after the re-latch delay period, the Schlage button will blink red.
3. If an invalid construction access user credential is presented, the lock will beep and
the Schlage button will blink red twice. See Construction access mode on page 5
for more information.
NOTE: Construction access mode is cancelled when the lock is reset to factory
L
defaults. When construction access mode is cancelled, the master construction
credential and all other credentials added using the master construction
credential will no longer function.
All information in the lock will be deleted and reset to factory defaults!

Level 1 factory default reset

Level 1 factory default reset will delete configurations and settings in the main
L
controller in the lock.
Main controller configurations that will reset to factory default include:
L
programming and user codes.
Level 1 factory default reset will not reset configurations and settings in the
L
reader.
1. Remove the top inside cover.
2. Press and hold the Schlage button until two (2) beeps sound (10 seconds).
3. Release the Schlage button.
4. Press and release the inside push button (IPB) three (3) times within 10 seconds. One
beep will sound and one red blink will occur with each press.
5. The Schlage button and IPB will both light green for one second and a one-second beep
will be heard. This indicates that the lock has been reset.
If the IPB is not pressed 3 times within 10 seconds, two beeps with two red blinks
L
indicate timeout.
6. Replace the top inside cover.

Level 2 factory default reset

Level 2 factory default reset will delete all configurations and settings in the lock
L
and the reader.
Reader configurations that will reset to factory default include: keypad format,
L
magstripe reader track, beeper on/off, and contactless card.
Days in Use counter and lock type configurations will not reset.
L
To complete Level 2 factory default reset, repeat steps 2 through 5 above within 10
seconds of the confirmation signals of Level 1 factory default reset. If more than 10
seconds pass after the confirmation signals of Level 1 reset, then Level 1 reset will be
repeated.

Reset to factory defaults

7 • Schlage • AD-250 user guide