Locks With Card Readers - Add Construction Access Mode User Credentials; Cancel Construction Access Mode; Test Lock Operation - Schlage PIB300 User Manual

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Locks with card readers – Add construction access mode user credentials
Construction
access mode
credential type
Normal use
construction
credential
Unlocks the lock
for relock delay
period
Toggle
construction
credential
Changes the
state of the lock
from locked to
unlocked or vice
versa

Cancel construction access mode

Do one of the following:
Program the lock with the SUS. See the SUS user guide for more information.
Reset the lock to factory settings. See Reset to factory defaults on page 7 for more
information.
When construction mode is cancelled, the master construction credential and all other
credentials added using the master construction credential will no longer function.
If you encounter problems while performing any of the following tests, review the installation
guide and correct any problems.
Mechanical test
1. Rotate the inside lever. Operation should be smooth, and the latch should retract.
2. Insert the key into the keyway and rotate the key or the key and lever to open the door.
Operation should be smooth, and the latch should retract.
Electronic test
Test the AD-250 in factory default mode
1. For locks with a keypad, press any number key. The lock will beep.
2. Press the Schlage button. The keypad should light blue for a few seconds.
3. Present a credential to the reader. The lock will beep and the Schlage button will blink
red one time. When the lock is in factory default mode, no credentials are accepted.
If the lock does not acknowledge the credential presentation, be sure that there is
L
data on Track 2 of the credential. Default settings require data on Track 2.
4. In the factory default state, locks with keypads, with or without additional credentials,
have a default PIN of 13579 and "#". To test, enter default PIN. The Schlage button will
blink and the lock will unlock.
6 • Schlage • AD-250 user guide
Steps to add construction access mode user credentials
1
Present
Green LEDs
master
blink
construction
credential to
reader
Present
Green LEDs
master
blink
construction
credential to
reader

Test lock operation

2
3
Present user
credential
within 20
seconds
Press and
hold Schlage
button while
presenting
user credential
within 20
seconds
4
Green LEDs
blink and
credential is
Repeat steps
added
3 and 4 for
additional
credentials.
Credentials
Green LEDs
added with
blink, 2 beeps
the master
will sound and
construction
credential is
credential will
added
have 24/7
access.
5