Network Connection; Ethernet Connection; Dip Switches - Schlage PIB300 User Manual

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Ethernet connection

Connect a live ethernet connection to the ethernet port on the PIM400-1501. The green LED
on the PCBA ethernet port will light up when a live network connection is present.
The PIM400-1501 is shipped with the factory default network settings shown below.

DIP switches

The four switches on S1 DIP switches configure the operating mode of the EP-1501 processor.
DIP switches are read on power-up except where noted. Pressing switch S2 causes the
EP-1501 to reset.
Switch
Switch
4
3
Off
x
x
x
Off
x
Off
x
x
On
All other switch settings are unassigned and reserved for future use.
Note: In order to ensure that the default login account is not enabled indefinitely,
L
the EP controllers have been changed as follows:
Even if no user accounts have been created, the default login account is not
automatically enabled.
Enabling the default user account: switch DIP SW1 from OFF to ON and log in within 5
minutes.
Rebooting the board or logging in within 5 minutes will disable the default account until
DIP SW1 is transitioned again.
"Password" is not a valid password for a user account as it matches the default login.

Network connection

Switch
Switch
2
1
Off
Off
x
On
On
Off
On
On
x
x
Normal operating mode
After initialization, enable default User Name (admin)
and Password (password). The switch is read on the
fly, no need to reboot.
Factory default network connection parameters
Network: Static IP address, 192.168.0.251
Subnet Mask: 255.255.0.0
Default Gateway: 192.168.0.1
DNS Server: 192.168.0.1
Host port: IP Server, no encryption, port 3001
Communication Address: 0
Schlage OEM Default Communication Parameters
With the Schlage OEM code, the network connection
parameters are set by DHCP. The DHCP hostname
is "MAC" followed by the 12 digit MAC address of the
device (e.g., MACxxxxxxxxxxxx).
If a different OEM code besides Schlage is
loaded into the PIM400-1501, the OEM default
communication parameters may be different than
DHCP.
Disable TLS secure link. Switch is only read when
logging on the web page.
Definition
9 • Schlage • PIM400-1501 user guide