Setting Up Sites and Readers

Configuring the Physical Reader

Getting to the
Setup Menu in
the Reader
54
While most of the information in the reader is controlled through HandNet, you
must initially set up certain settings in the reader so it can communicate with
HandNet. You do this through the command menus on the reader.
For readers with a network (ethernet) card: The IP address in this reader
must match the IP address on the Connection tab in Site Properties; see
page 39.
For a reader connected by serial port or connected as part of a chain
of readers: The address in the reader must match the address on the
General tab in Reader Properties; see page 45. The serial settings must
also be correct, and the baud rate must match the baud rate on the
Connection tab in Site Properties; see page 35.
We do not recommend changing any other settings through the reader
command menus. All other settings can be controlled through Reader
Properties in HandNet; see page 45 (if you were to make other changes directly
in the reader, these would be overridden by the settings in HandNet when you
enabled the reader).
1. Enter command mode on the reader:
If you have a HandKey II or HandKey CR reader: Press CLEAR, and
then press ENTER.
If you have an ID3D HandKey reader: Press # AND * (you can press
them at the same time, or one after the other).
If you have not used the reader with HandNet before, or if you have used it with
HandNet and cleared its memory, the display looks like this.
ENTER PASSWORD
Type the password for the setup menu and press ENTER or #. If you have not
changed it, the password is two (2).
If you have previously used the reader with HandNet and are reconfiguring it for
another site or location, you may see:
READY:
*:
If the display looks like this, type your user ID and press ENTER or #. The
reader will ask you to place your hand. Once you place it, you should then see
the Enter Password display shown above. Type the password for the Setup
menu and press ENTER or #. If you have not changed it, the password is two
(2).