Schlage PIB300 User Manual page 371

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

HandReader Maintenance
!
NOTE
Cleaning the
Hand Reader
!
NOTE
User Score
A minimum amount of system maintenance is required to keep HandReaders fully
functional. HandReaders should be cleaned periodically to prevent an accumulation
of dust from affecting the HandReader's readability. User Scores should be reviewed
periodically to ensure the HandReader is performing properly.
There are NO user serviceable parts inside the HandReader.
Once a HandKey system is in operation there are three HandReader commands that can
assist with system maintenance. These commands are performed through the Service
Menu. The instructions for these commands begin on page 37.
• Calibrate – View Hand Reader exposure values.
• Status Display – Display Hand Reader input/output status, the hand read score of the
last user to verify on the system.
• Network Status – Display the network communication status of Hand Readers in the
HandKey system (master Hand Reader only).
Inspect and clean the HandReader regularly to maintain optimum performance. Clean
the platen, side mirror, reflector, and the window above the platen using a clean cloth
dampened with ordinary, non-abrasive window cleaner (see Figure 14-1). Start at the rear
corners of the platen and work your way forward.
DO NOT SPRAY CLEANING FLUID DIRECTLY INTO OR ON THE HAND READER.
Periodically check users' scores (refer to the Read Score section on page 48). Scores
should average under 30. Occasionally a user will score above 30. This is not necessarily
an indication of poor performance. If a number of scores average over 30, clean the
HandReader and check scores again. If scores remain high, or if users are experiencing
frequent rejections, run the Calibration command (see page 38).
Figure 16-1: HandReader Cleaning