Schlage PIB300 User Manual page 1070

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

1000 User Manual Programming Guide
Programming Credentials / Beeper Settings
Programming Credentials
Programming Credentials / Beeper Settings
 Creating a programming credential deletes all factory codes.
 Using a programming credential puts lock into the programming mode.
 Using a programming credential will not unlock the lock.
 Only one programming credential is allowed.
 Any programming credential can be used to manually program any user credential.
To Create a Programming Credential:
Refer to your lock's installation manual when performing the following steps.
1. The inside escutcheon cover must be removed.
2. On the inside escutcheon PCB, press & release the INI button 3 times.
> Red LED comes on and stays on.
3. Present the credential to the reader.
> Green & red LEDS alternately flash, which indicates acceptance.
> Green LED goes out, red LED stays on.
4. Press & release the INI button once.
> Red LED goes out.
Beeper Settings
The factory default beeper setting is:
Turning the beeper ON for all functions:
Programming Code * (or iButton), 99 *, 3 *, 7 *
Turning the beeper OFF for all functions:
Programming Code * (or iButton), 99 *, 3 *, 0 *
The beeper can also be:
To change the beeper settings, enter:
Programming Code * (or iButton), 99 *, 3 *, refer to beeper setting number below, *
NOTE: There is no beeper during Error Code flashing regardless of beeper setting.
57001-C
OFF for all functions.
ON for some functions and OFF for others.
Page 4 of 8