Mechanical Installation
NOTE
Attaching the
HandPunch
14
Wall Plate
C L
Finished Floor
Figure 3-2: HandPunch Wire Routing Layout
Dust and debris surrounding the HandPunch can drastically affect the terminal's
operation. It is important to ensure the HandPunch mounting location is free from dust
and debris.
1. Remove the HandPunch from its carton.
2. Align the sleeves of the back plate with the pins of the wall plate and slide the
HandPunch to the left as shown in "Figure
SURFACE
CONDUIT
ENTRY POINT
HandPunch
(108 cm)
3-3".
C L
50" Reference
(127 cm)
to Top of
Wall Plate
42.75"
(108.6 cm)
42.5"