Input Configuration (Digital Analyzer); Table 4-32 Digital Analyzer > Input Config Menu Description - Keysight U8903B User Manual

Performance audio
Hide thumbs Also See for U8903B:
Table of Contents

Advertisement

4
Audio Analyzer Measurement Functions

Input Configuration (Digital Analyzer)

The input configuration for digital analyzer is displayed as shown in Figure 4-63.
Figure 4-63
Table 4-32
Digital Analyzer > Input Config menu description
Menu
Description
Press the Connector softkey to select the connector type.
– UnBal
Unbalanced connector type routes the digital signal from the BNC input connector at the rear panel to the
digital analyzer.
– Bal
Balanced connector type routes the digital signal from the XLR input connectors in the rear panel to the digital analyzer.
Connector
– Optical
Optical connector type routes the digital signal from the TOSLINK input connector at the rear panel to the
digital analyzer.
– DSI
DSI connector type routes the digital signal from the 25-pin female D-SUB connector at the rear panel to the
digital analyzer.
Press the Impedance softkey to select the input impedance.
Unbalanced connector type
– 75 Ω
Impedance
– HiZ
Balanced connector type
– 110 Ω
– HiZ
248
Digital Analyzer > Input Config menu page
Keysight U8903B User's Guide