Note:
Check also the application documentation for trouble-shooting information.
Note:
If the indicator starts to blink red, check:
IP address
Network connections
License
Module key
If everything seems to be OK but the function indicator still flashes, the fault is probably
located outside the Elise 2 Server (AIWS Hardware):
Check the other System 900 units according to document System Installation, On-site
Paging System, TD 90227GB, or contact your dealer.
2. Open the administrator page in a browser and navigate to "Troubleshoot". Use the
information log and tools given to test that Elise 2 Server (AIWS Hardware) is functioning
properly.
3. Replace the cover.
4. When all other units are installed, perform the system test described in System Installation,
On-site Paging System, TD 90227GB.

Clock synchronisation and time settings

The clock in different Elise 2 Server (AIWS Hardware)s can be set from the web browser, A-bus
(i.e. Central Unit in System 900) or a time server. To be able to synchronize the clocks in
different Elise 2 Server (AIWS Hardware)s a time server has to be used. Depending on software
application and license, an Elise 2 Server (AIWS Hardware) can be used as time server. An
external time server supporting the Network Time Protocol (NTP) can also be used. Normally
the Elise 2 Server (AIWS Hardware) that is used as time server synchronizes with an external
time server, and then all other Elise 2 Server (AIWS Hardware) use that Elise 2 Server (AIWS
Hardware) as the time server.
To select time source do as follows:
1. Open the administration pages of the Elise 2 Server (AIWS Hardware) by entering
"xxx.xxx.xxx.xxx/admin" in the address field in the web browser.
2. Click on "Settings" in the left menu.
3. Select time source; Web browser, A-bus or Time server.
Note:
Not all system's Central Unit can provide the time.
Note:
Independent of time source the Elise 2 Server (AIWS Hardware) can handle different time
zones and adjust the clock according to daylight saving time.