Installing and operating the IPBS and IPBL
2. Select TCP in the Type drop-down list.
3. Enter the IP address of the logging server in the Address text field.
4. Enter the Port of the logging server in the Port text field.
5. Click OK.
Storing the Syslog entries in a Syslogd
1. Select General > Logging.
2. Select SYSLOG in the Type drop-down list.
3. Enter the IP address of the syslogd in the Address text field.
4. Enter the desired syslogd message class in the Class text field.
5. Click OK.
Storing the Syslog entries on a Web Server
1. Select General > Logging.
2. Select HTTP in the Type drop-down list.
3. Enter the IP address in the Address text field.
4. Enter the "relative URL of the form program" on your web server in the Path text field.
5. Click OK.
Note:
The IPBS will make an HTTP GET request to the web server on the registered
Note:
URL followed by the URL-encoded log entry.
Example:
Enter the value /cdr/ cdrwrite.asp in the URL-Path field if a page is on the web server
with the name /cdr/cdrwrite.asp with a form that expects the log message in the msg
parameter.
In this example, the IPBS will make a GET
/cdr/cdrwrite.asp?event=syslog&msg=logmsg request to the server.
Forwarding alarms and events
You can forward alarms and events to an HTTP server destination. Typically, this destination
can be a Master base station. This configuration for forwarding alarms and messages can be
done in the Pari Master (DECT > Radio config) or locally as described below.
1. Select General > Logging.
2. If the HTTP server destination requires HTTPS, then select HTTPS in the Type drop-down
list.
3. Enter the IP Address of the IPBS, where you want to have an overview of all faults, in the
External HTTP Server Address field.
130