Installing and operating the AIWS and the AIWS2
Description of the fault, as defined in the module
Type of module
IP address and host name of the module that generated the fault
By expanding the fault in the list, additional information about the fault is shown containing:
Fault ID
This is used to reference a persistent fault when it later is reset
Fault code
Description of the fault code
Extended address information showing the system, bus type and module address
In the figure below the system is 00, the bus type is 1 and the module address is 0A.
Figure 138: The Active faults page
Persistent faults will remain in the list until the module sends a status message confirming that
the module is working properly again. It is also possible to delete the fault in the list by clicking
the delete symbol.
Note:
If the IP address or license is changed in AIWS, the faults reported for the
Note:
previous IP address/license will remain since no confirmation can be received.
These faults must be manually deleted.
The active faults list page has to be manually updated by clicking the Update Page link
uppermost on the page. See
Installing Elise 2 Server (AIWS Hardware)
Resetting the error relay
The error relay can be reset manually from the Active Faults page.
1. Click Configuration on the start page.
2. Select Status > Active Faults in the menu on the Configuration page.
456
Avaya DECT R4 - Installation and Maintenance Guide
Function Indicator and Error Relay Output
on page 523.
on page 519 and