The USB Interface supports USB 2.0 Full speed. One Mini-B Receptacle USB connector is
used. The USB connection is used for communication with a PC. Power over USB is not
supported.
Figure 60: Connection to PDM
Software installation
The charger is delivered with pre-installed software and it is possible to upgrade the charger
software. Please see

Advanced Charger configuration

Each Advanced Charger need access to DHCP to receive an IP address automatically. If no
DHCP is accessible it is possible to configure the IP address with PDM or AIWS.
If the Advanced Charger is configured to run DHCP, connect the network cable and the charger
will automatically receive an IP address. If the charger is not configured to run DHCP the
charger will use the setup IP addresses.
The following parameters exist for Advanced Charger and can be changed via PDM or AIWS:
Parameter
Ethernet Bit rate
Ethernet connector
Ethernet duplex
DHCP Enabled
Charger IP address
Subnet mask
Default gateway IP address
DNS IP address
Avaya DECT R4 - Installation and Maintenance Guide
Software update
1
1
1
2
on page 276.
Description
auto (default)
auto (default)
auto (default)
Yes (default), No
192.168.0.101 (default)
255.255.255.0 (default)
192.168.0.1 (default)
192.168.0.2 (default)