Installing and operating the AIWS and the AIWS2
In IP -DECT under DECT Interface remove the entries (or just configure to 0.0.0.0) for
IP-DECT IP address and Secondary IP-DECT IP Address. Set multiple Locations
(former IP-Regions) to Yes
In Phonebook select Location settings (former IP-Region settings). Set Digit Treatment
to enable. Now configure the digit treatment settings. For each Location with different digit
treatment rules an own entry using the appropriate Location ID (former IP-Region ID)
needs to be created. Each IPBS Master needs to refer to one of these Location IDs. IPBS
Masters and Standby Masters in the same Location area can refer to the same Location
ID. It's recommended to use the same Location IDs as used on the Communication
Manager side (IP Region page).
In UNS under Other select Default Category. Make sure the Messaging handler service
name is set to DGH (Device Group Handler).
On AIWS device manager:
Make sure that the following two entries are identical:
- The entry in the Number field of a handset device configured in the Numbers tab and
- the Number (extension number) of the handset assigned in the IPBS Master Users
tab.
Otherwise the messaging and centralized phonebook access won't work. This restriction
only exists in systems using multi IPBS Masters on one AIWS.
On each Base Station Master and Standby master:
In UNITE > SMS, you will need to configure the Location ID (former IP-Region ID)
according to the digit treatment rules for the corresponding Location configured on the
AIWS.
Note:
Note: In the Standby Master it's recommended to use the same Location ID as its
Note:
Master Base Station is configured.