Installing and operating the Rackmount Charger
Note:
It may be necessary to import the parameter definitions file that is included in the
Note:
software package.
The package is provided by your supplier. The PDM/AIWS/AIWS2 used may
differ from the version that is described here.
Follow these instructions to set Rackmount Charger parameters:
1. Check that the Rackmount Charger is connected to PDM/AIWS.
2. In PDM or the Device Manager in AIWS, click on the Numbers tab.
3. Select the Rackmount Charger device that you want to change parameters for.
4. In the Number menu, click Edit.. The Edit parameters window opens.
5. Edit the parameters you want to edit.
6. Click OK.
Rackmount Charger does not appear in AIWS
If the Rackmount Charger does not appear in the AIWS Device Manager, the Service Discovery
might not be working in the customers network setup.
In this case connect the Rackmount Charger to PDM and edit the following parameters:
Service Discovery Enabled: No
DH IP address (one DH only): Enter AIWS IP-Address
308
Avaya DECT R4 - Installation and Maintenance Guide
1
Ethernet connector
1
Ethernet duplex
DHCP Enabled
Charger IP address
Subnet mask
Default gateway IP address
DNS IP address
Charger IP port
Service Discovery Enabled
Service Discovery Domain
DH IP address (one DH only)
DH IP port
1. Currently only "auto" setting is available
auto (default)
auto (default)
Yes (default), No
192.168.0.101 (default)
255.255.255.0 (default)
192.168.0.1 (default)
192.168.0.2 (default)
12346 (default)
Yes (default), No
Name of domain
192.168.0.3 (default)
10147 (default)