Installing Elise 2 Server (AIWS Hardware)
1. Use pliers to break off a suitable section.
Run the wiring out through the partition. Wiring can be run three ways from the Elise 2
Server (AIWS Hardware):Remove the rectangular covers and run the cabling out
1
2
through the side (1).
Break off sections at short side of case and run the cabling downwards (2).
Run the cabling through the round holes at the bottom of the case (3).
2. Secure the wiring with cable straps.

Selection of A or B-bus

When modular bus cabling is used for connection of the System 900 bus the A-bus is used
default. To use the B-bus, remove the 0 ohm resistors R111 and R112 from the circuit board and
solder jumper points S1 and S2 (R111 and R112 are situated on the bottom side of the circuit
board). See
figure 172
534
Avaya DECT R4 - Installation and Maintenance Guide
3
3
2
1
on page 535.