Sun Java Runtime Environment (JRE) version 6 or higher.
●
USB port. USB 1.1 required, USB 2.0 supported.
●
Ethernet port 10/100 Mbit/s.
●
Installation and configuration
!
Important:
Installation of the unit is NOT permitted in a hazardous area. The unit must be
Important:
installed by an authorized person only.
Rackmount Charger installation
General
Note:
The unit shall be installed by authorized personnel only.
Note:
The units shall be placed in a dry environment with a temperature range from
●
+5° C to + 40° C (41° F to 104° F).
The units shall be mounted on a vertical wall.
●
Avoid mounting the Rackmount Charger in a sunlit place. This can affect the charging
●
capacity.
Avoid mounting the Rackmount Charger where radio/network coverage is not sufficient.
●
This can reduce the messaging capacity.
The unit shall be mounted on concrete or plaster walls only.
●
If the Rackmount Charger is connected to a power supply via an AC wall plug, serial power
●
supply connection is not allowed.
If the Rackmount Charger is connected to a power supply via an AC wall plug, the
●
socket-outlet shall be situated near the equipment and shall be easily accessible.
If the Rackmount Charger is connected to a power supply via a fixed connection, a readily
●
accessible disconnect device shall be incorporated in the building installation wiring.
Delivery includes:
Rackmount Charger
●
Power supply cord including IEC C14 connector (male)
●
Avaya DECT R4 - Installation and Maintenance Guide
Installation and configuration
02/2016