1. Click Configuration on the start page. The Configuration page appears.
2. Select Other Settings > Advanced Configuration in the left menu in the AIWS
Configuration page. The Advanced Configuration page appears.
3. Under Other, click UNS. The UNS page appears.
Figure 144: The UNS page.
Operating mode
Operating mode is changed in systems with an Unite CM (Connectivity Manager) only.
1. To set Operating mode, click Operating mode. The UNS Operating Mode page appears.
Figure 145: The UNS Operating Mode page.
2. In a system with a Unite CM, set operating mode to Forwarding and enter the Unite CM IP
address.
3. Click Activate.
Default category
The UNS Default Category is used to decide where messages from the AIWS shall be sent. The
messaging handler is default set to localhost (127.0.0.1) which is the internal message group
handler in the module. This can be changed if you want to use a messaging handler in another
module. This parameter is changed when the IP-DECT system is connected to another module.
1. To set Default Category, click Default Category. The UNS Default Category page
appears.