Figure 67: The rectangular cover that shall be removed and exchanged with a cable
support holder with a mains power supply cord run through it
5. Remove the C14 connector from the additional charger. Cut and strip the mains power
supply cord coming from the additional charger to the length required.
6. Run the power supply cord from the additional charger through the cable support holder of
the previous charger, see
Figure 68: Securing the mains power supply cable
7. Connect the power supply cord from the additional charger to the unused terminal block in
the charger closer to the AC power source. Note the embossed markings L, earth symbol
and N, see
Avaya DECT R4 - Installation and Maintenance Guide
figure 68
figure
69.
Installation and Configuration
02/2016
291