ELECTRICAL SYSTEM
Item
Designation
Chime
In instrument panel (on right side; behind glove box)
Seat belt
&
key warning chime
Timer
Under instrument panel on driver's side
Rated voltage
12V
Rated current
7A or less
Rated revolutions
55 rpm
Rated load
2.4 N·m (24 kg-em, 21 in-Ib)
S tailing current
ISA or less
Power window (Option)
Stalling torque
S.3 N·m (S5 kg-cm, 74 in-Ib)
Working voltage
IOV - 15V
Working
-25 - SO°C (-13 - 176°F)
temperature
Raising or
Approx. 3.5 seconds (varies depending on ambient temperature,
lowering time
working voltage and type of glass)
Excess
Approx. 196 N (20 kg, 44 lb)
raising force
(varies depending on ambient temperature, working voltage and type of glass)
Motor type
Electromagnetic type
Heater fan
Input
12V-160W or less
Switch position
On heater and ventilator control panel
Motor type
Electromagnetic type
Cooling fan
Input
12V-120W or less
Switch position
On radiator
Input
12V-9.6W or less
Fuel pump
Switch position
In ignition-starter switch
15-7