HEATING, VENTILATING AND AIR-CONDITIONING SYSTEM
2)
Blower Motor Diagnoses
Blower motor inoperative
I
I
Check 20A fuse for blower relay, and 15A fuse
between ignition switch and blower relay.
I
I
Fuse blown
Fuse OK
I
Locate short-circuited spot and repair or replace
Ground black wire leading to relay
faulty parts.
I
Blower runs.
Blower does not run.
1
Check lead wire connection.
Ground one of lead wires, yellow/green (Extra
When no problem is found, replace relay.
Hi speed), yellow/black (Hi speed), yellow/red
(Med. speed), yellow (Low speed) leading to
.
blower switch.
'~~l?
-
I
Blower runs.
Blower does not run.
I
Check ground circuit connection and lead wire
connection. When no problem is found, replace
Ground red/white wire of blower motor.
blower speed switch.
I
Blower runs.
Blower does not run.
I
Check connection of resistor. When no problem is
Connect 12-volt test light to green/white wire lead-
found, replace resistor.
ing of blower motor.
;,
.\\,.
.'
I
.'",",
",m
.'1~~~
Light ON
Light OFF
1
,,:
.
Check lead wire connection. When no problem
..
-.'
Check connector and check fuse holder, too.
is found, replace blower motor.
Repag or replace damaged parts, if any.
13-45