Subaru 1600 Service Manual page 548

Table of Contents

Advertisement

HEATING, VENTILATING AND AIR-CONDITIONING SYSTEM
Item
Specifications
Fan type
Silocco fan type
Blower fan
Outer diameter x width
140 x 65 mm (5.51 x 2.56 in)
Power consumption
160Wat12V
Condenser fan
Motor type
Print type
(Sub fan)
Power consumption
95 Wat 12 V
Fan outer diameter
300 mm
(I 1.81 in)
Radiator fan
Motor type
Magenet type
(Main fan)
Power consumption
120Wat12V
Fan outer diameter
280 mm
(I 1.02 in)
Idling speed with F.I.C.D. in operation
950
±
50 rpm
Low-pressure-switch working pressure
196 ± 20 kPa (2 ± 0.2 kg/cm
1
,
28 ± 2.8 psi) G
High-pressure switch
2,403 ± 98 kPa (24.5 ± 1.0
kg/cm z ,
348 ± 14 psi) G (ON
-+
OFF)
1,912 ± 98 kPa (19.5 ± 1.0
kg/cm z
,277 ± 14 psi) G (OFF
-+
ON)
Pressure switch (Main fan control)
1,569 ± 78 kPa (16.0 ± 0.8
kg/cm z
,228 ± 11 psi) G (ON
-+
OFF)
1,275 ± 98 kPa (13.0 ± 1.0
kg/cmz,
185 ± 14 psi) G (OFF
-+
ON)
13-3