Ancd: Assignment Of Night Connection Data - NEC NEAX 7400 IMX Command Manual

Table of Contents

Advertisement

ANCD: Assignment of Night Connection Data

1. General
This command is used when the Power Failure Transfer (PFT) circuit card is controlled by the external key.
2. Precautions
1.
When the "PFT control by the external key" is required, the following data assignments are needed:
(a) AUNT command, TYPE=2 (PFT)
(b) AEKD command
(c) ANCD command
(d) ACSI command, CSI=4 (Direct-in Termination (Night Mode))
3. Data Entry Instructions
MG/NCU/ PKG
Enter the data assigned by the AUNT command.
MODULE
GROUP
(MG)
PFT CARD
PORT NUMBER
NUMBER
OF PFT CARD
(NCU PKG)
0-3
The port parameter corresponds to the circuit
number of the PFT card.
ROUTE
NUMBER
(PORT)
(RT)
0-11
1-255
RT/TK
Enter the trunk route number (RT) and the trunk number
(TK) connected to the corresponding circuit number of PFT
card.
ND-70348 (E)
PORT
TRUNK
REMARKS
NUMBER
(TK)
ANCD
CHAPTER 4
Page 580
Revision 3.0