LOGICAL ROUTE (LGRT) 1-899
FUSION POINT CODE (FPC) 1-253
ROUTE NUMBER (RT) 1-255
Release timing for outgoing trunk connection.
0 = 608 msec.
2 = 288 msec.
4 = 416 msec.
31
OGRL
6 = 544 msec.
8 = 672 msec.
10 = 800 msec.
12 = 928 msec.
14 = 1056 msec.
Release timing for incoming trunk connections.
0 = 288 msec.
2 = 288 msec.
4 = 416 msec.
32
ICRL
6 = 544 msec.
8 = 672 msec.
10 = 800 msec.
12 = 928 msec.
14 = 1056 msec.
Trunk Hold Timing.
0 = 10 sec.
2 = 4 sec.
4 = 8 sec.
33
HD
6 = 12 sec.
8 = 16 sec.
10 = 20 sec.
12 = 24 sec.
14 = 28 sec.
Ground Timer
Outgoing inhibit timing after trunk release.
0 = 3072 msec.
2 = 1024 msec.
4 = 2048 msec.
34
GUARD
6 = 3072 msec.
8 = 4096 msec.
10 = 5120 msec.
12 = 6144 msec.
14 = 7168 msec.
1 = 224 msec.
3 = 352 msec.
5 = 480 msec.
7 = 608 msec.
9 = 736 msec.
11 = 864 msec.
13 = 992 msec.
15 = 1120 msec.
Note
1 = 224 msec.
3 = 352 msec.
5 = 480 msec.
7 = 608 msec.
9 = 736 msec.
11 = 864 msec.
13 = 992 msec.
15 = 1120 msec.
1 = 2 sec.
3 = 6 sec.
5 = 10 sec.
7 = 14 sec.
9 = 18 sec.
11 = 22 sec.
13 = 26 sec.
15 = 30 sec.
1 = 512 msec.
3 = 1536 msec.
5 = 2560 msec.
7 = 3584 msec.
9 = 4608 msec.
11 = 5632 msec.
13 = 6656 msec.
15 = 7680 msec.
ND-70348 (E)
ALRNN
REMARKS
Normally assign
data "0".
For ISDN, see Table
(page 445)
4-25
.
(Examples of Route
Class Settings)
Normally assign
data "0".
For ISDN, see Table
(page 445)
4-25
(Example of Route
Class Settings).
Note:
160 msec. in
case of Loop
Dialing Trunk.
Normally assign data
"0".
Normally assign
data "0."
For ISDN, see Table
(page 445)
4-25
(Example of Route
Class Settings).