NEC NEAX 7400 IMX Command Manual page 429

Table of Contents

Advertisement

FUNCTION
KPST
Duration of KP sending
0= 48 msec.
2= 64 msec.
4= 80 msec.
6= 96 msec.
8= 112 msec.
10= 128 msec.
12= 144 msec.
14= 160 msec.
73
(In case of MFC)
0= 12.0 sec.
2= 7.0 sec.
4= 10.0 sec.
6= 13.0 sec.
8= 16.0 sec.
10= 20.0 sec.
12= 24.0 sec.
14= 28.0 sec.
KPPT
Pause after KP sending
0= 48 msec.
5= 88 msec.
7= 104 msec.
12= 144 msec.
14= 160 msec.
(In case of MFC)
74
0= 12.0 sec.
2= 7.0 sec.
4= 10.0 sec.
6= 13.0 sec.
8= 16.0 sec.
10= 20.0 sec.
12= 24.0 sec.
14= 28.0 sec.
STC
Stop Code
0-11= Not used
75
13= Not used
15= MF (for MF signaling)
MC
MP Start Cause
76
0= As per ST
MT
MF Frequency
77
0= DTMF (4×4)
TONE
TONE Designation for TRK Call Termination
0= DT
78
LGRT
1-899
1= 56 msec.
3= 72 msec.
5= 88 msec.
7= 104 msec.
Note
9= 120 msec.
11= 136 msec.
13= 152 msec.
15= 168 msec.
1= 5.5 sec.
3= 8.5 sec.
5= 11.5 sec.
7= 14.5 sec.
9= 17.5 sec.
11= 22.0 sec.
13= 26.0 sec.
15= 30.0 sec.
1= 56 msec.
6= 96 msec.
8= 112 msec.
Note
13= 152 msec.
15= 168 msec.
1= 5.5 sec.
3= 8.5 sec.
5= 11.5 sec.
7= 14.5 sec.
9= 17.5 sec.
11= 22.0 sec.
13= 26.0 sec.
15= 30.0 sec.
12= MF
14= DTMF
1= Not used
1= MF (2 out of 6)
1-15= Not used
ND-70348 (E)
ARTDN
REMARKS
When the monitor sig-
nal is Reverse and the
data is set to "0", KP
sending is stopped by
reserve signal monitor
at the related distant
office.
Note:
Use this when
ONSG/INSG =
4.(MF)
Note:
Use this when
ONSG/INSG
= 4.(MF)
Use this when ONSG/
INSG = 4.(MF)
This data must always
be set to "0".
Use this when ONSG/
INSG = 4.(MF)
This data is effective
when 2 (Second Dial
Tone) is set in ARTDN,
ISGS = 3.
CHAPTER 4
Page 422
Revision 3.0

Hide quick links:

Advertisement

Table of Contents
loading