Ashc: Assignment Of Station Hunting Group - Circular - NEC NEAX 7400 IMX Command Manual

Table of Contents

Advertisement

ASHC: Assignment of Station Hunting Group - Circular

1. General
This command is used to assign the data related to the Station Hunting - Circular service feature.
2. Precautions
1.
This command is also used to modify and delete the Station Hunting - Circular service feature related data.
2.
The maximum number of member stations within a Hunting Group is 100, not including the Secretary Sta-
tion. It cannot be executed to assign a station belongs to other Station Hunting Group in duplicate.
3.
When assigning the Circular Hunting member station data, the data entered in the STN text box must be
reentered as CNT 1 text box.
Example: When the station numbers 300, 301, and 302 are the members of the Station Hunting - Circular
group, assign the data as follows:
STN = 300
CNT 1 = 300
CNT 2 = 301
CNT 3 = 302
4.
The applicable tenant number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.
5.
Press ESC to skip forward to the SECRETARY parameter when all the desired member stations have been
entered.
6.
Enter space (blank) in the SECRETARY parameter if a secretary station is not required.
ND-70348 (E)
ASHC
CHAPTER 4
Page 515
Revision 3.0

Hide quick links:

Advertisement

Table of Contents
loading