ALMG: Assignment of Alarm Grade Data
1. Functional Outline
This command is used to make a flexible change of the system message output grade and alarm lamp grade. The
SV8500 user can give a proper output grade and alarm lamp grade to each system message according to their
requirements.
Output grade - - - - - - - Specifies whether the fault information is output on system alarm lamp and system
Alarm lamp grade - - - Specifies how to indicate fault information.
When no data is assigned, the default alarm grades are automatically applied.
This command cannot change the alarm grade for System Message [6-A].
Note 1:
Use LLMG (Listup of Alarm Grade Data) command TYPE=3 to output the default value of alarm lamp
Note 2:
grade for system message.
"Delete" in this command means to turn back the changed output grade and alarm lamp grade data
Note 3:
to default value.
2. Parameters
Input data
FK:
FI:
LMP:
GRD:
When lower grade of GRD is assigned than SYSM GRD, system message is not output.
Note:
SYSM GRD: System Alarm Lamp Output Grade
message.
Fault Message Kind (0-7, 10-17, 20-27, 30-37)
Fault Message Index (A-Z)
Alarm Lamp Grade (0-3)
Specifies the lamp kind for system alarm lamp and system message output.
0=NON lamp ON
1=SUP lamp ON
2=MN lamp ON
3=MJ lamp ON
Output Grade (0-3)
Specifies the output grade for system alarm lamp and system message.
Specifies the output grade of system alarm lamp and system message on a node basis,
depending on the setting on ASYD SYS1 INDEX91 bit2 and bit3.
0=Output all fault