Aspf: Assignment Of Special Access Code Floor - NEC NEAX 7400 IMX Command Manual

Table of Contents

Advertisement

ASPF: Assignment of Special Access Code Floor

1. General
This command is used to assign Floor Data for the Access Code of the Floor Service.
2. Precautions
1.
This command is used for the Hotel Application only.
2.
When assigning data by this command, the ASYD command, SYS 1, INDEX 165, bit7 = 1 (Floor Service
is provided) must have been assigned.
3.
When assigning data by this command, the Access Code for Floor Service must have been assigned by the
AASP/AGSP command, SSC=2, SID 56.
4.
When deleting data for this command, the Access Code for Floor Service must be deleted in advance by
the AASP/AGSP command.
3. Data Entry Instructions
0 : Main Building
D/N
1 : Annex 1
D : Day Mode
2 : Annex 2
N : Night Mode
3 : Annex 3
CALLED PARTY
INFORMATION
DAY/
NIGHT
TENANT
MODE
NUMBER
(D/N)
(TN)
D/N
NO.
Enter SERVICE INDEX NUMBER
(NO.) assigned in the AASP/AGSP
command.
ANX
CALLING PARTY INFORMATION
SERVICE
ANNEX
INDEX
(ANX)
NUMBER
0-3
(NO.) 0-15
Ground/Underground
0 : Ground
1 : Underground
Floor Number (1-127)
GROUND
FLOOR AND
FLOOR
ABOVE/
NUMBER
BELOW
(FLR)1-127
(G)
0/1
G
ND-70348 (E)
FLR
CALLED
NUMBER
(DC)
Max. 6 digits
DC
Enter the called number such as a station
number.
ASPF
CHAPTER 4
Page 802
Revision 3.0
Printed in Japan
0103