3. Data Entry Instructions
Check the required parameter according to each terminal.
RT:
SFC:
C_RT: Connection Route Number [1-1023]
NODE: Enter the Node Number on which IPTRK card is accommodated
IPG:
INCOMING TERMINAL
(IC TERMINAL)
[RT/SFC/C_RT/NODE/IPG]
IC TERMINAL/OG TERMINAL
External Route Number for the trunk [1-255]
Service Feature Class for the station [0-15]
(Node Number is assigned by the ANTI command). [Max. 3 digits
Note 2
(0-9, *, #, P)]
IPELC Group Data [0-127]
OUTGOING TERMINAL
(OG TERMINAL)
[RT/SFC/C_RT/NODE/IPG]
Assign the PAD value within the range of 0dB-16dB (1-15).
PAD value for "SFC (station)" is fixed to "1 (PAD OFF)".
Note 4
See
ND-70348 (E)
Note 1
Note 3
INCOMING PAD
OUTGOING PAD
(IC PAD)
(OG PAD)
[1-15]
IC/OG PAD
for "IPG" setting.
REMARKS