K-Ccis Programming; Digital Trunk Data Assignment; Table 3-1 Digital Trunk Data Programming Assignments - NEC Univerge SV9100 Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

System Data Programming
S
1
K-CCIS P
ECTION
This chapter lists the Programs that must be assigned to support K-CCIS. The
Programming used depends on the K-CCIS features that are used. The tables
provided in this section provide a complete list of the required Programs that support
the function (e.g., Digital Trunk Assignment, CCH Assignment, Numbering Plan
Assignment).
At the end of this section, programming samples are provided for Open and Closed
Numbering Plans.
1.1
Program/
Item No.
10-03-01
10-03-02
10-03-03
10-03-04
10-03-05
SV9100 Networking Manual
<US Only>
ROGRAMMING

Digital Trunk Data Assignment

Use these programming assignments to indicate to the system where (which slot)
the GCD-CCTA blade is located, the signaling format the GCD-CCTA blade uses,
and to assign other information relating to the trunks.

Table 3-1 Digital Trunk Data Programming Assignments

Description/Selection
Blade Setup – Logical Port
Number
Blade Setup – Frame Type
Setup
Blade Setup – Zero Code
Suppression Setup
ZCS_B8ZS
Blade Setup – DTI<->
CSU Distance Setup
Blade Setup – T1 Clock
Source Master/Slave
Chapter 3
Assigned Data
0 ~ 400
The GCD-CP10 automatically
defines each blade during
installation.
default
0 = D4 (
)
If 56 K K-CCIS is used. 24
(12 Multiframe)
Multiframe (ESF) must be
1 = ESF
assigned.
(24 Multiframe)
default
0 = B8ZS (
)
1 = AMI/ZCS
default
0 = 0~ 133 feet (
)
Maximum distance back-to-back
1 = 133 ~ 266 feet
T1s can be connected without
2 = 266 ~ 399 feet
CSU/DSU service.
3 = 399 ~ 533 feet
4 = 533 ~ 655 feet
0 = Internal (default)
Define the Master (Internal) or
1 = External
Slave (External) clock source.
UNIVERGE
®
SV9100
Comments
3-1