Afpd: Assignment Of Fusion Tandem Pad Data For Ldm - NEC NEAX 7400 IMX Command Manual

Table of Contents

Advertisement

AFPD: Assignment of Fusion Tandem PAD Data for LDM

1. General
This command is used to assign PAD data for connection route. This command is available for the software Re-
lease 3 or later.
2. Precautions
1.
This data has priority over the data assigned by PAD, ACRD.
2.
When a data is input on this command, the data in the ACRD CDN6: PAD must be "7".
3. Data Entry Instructions
When TYPE = 1 is assigned
TYPE
1 = ICRT→C_RT
TYPE OF CONNECTION
INCOMING ROUTE
(TYPE)
1
1
1
Assign the outgoing connection route
number Originated to the outside of the
node
When TYPE = 2 is assigned
TYPE
2 = C_RT→C_RT
TYPE OF CONNECTION
INCOMING ROUTE
(TYPE)
(IC_C_RT) 1-1023
2
2
2
PAD value differs depending on the specification of each circuit card. As to the detail setting of PAD
Note:
value on each circuit card, refer to the Circuit Card Manual or related system manuals.
IC_RT
Assign the incoming route number
OUTGOING
(IC_RT)
CONNECTION ROUTE
1-255
(OG_C_RT) 1-1023
OG_C_RT
IC_C_RT
Assign the incoming route number
OUTGOING
CONNECTION
CONNECTION ROUTE
(OG_C_RT) 1-1023
OG_C_RT
Assign the outgoing connection
route number
ICPAD
1-14 =
Note
15 = PAD OFF (0dB)
INCOMING PAD DATA
OUTGOING PAD DATA
(ICPAD)
1-15
OGPAD
Note
1-14 =
15 = PAD OFF (0dB)
OGPAD
Note
1-14 =
15 = PAD OFF (0dB)
INCOMING PAD DATA
OUTGOING PAD DATA
(ICPAD)
1-15
ICPAD
Note
1-14 =
15 = PAD OFF (0dB)
ND-70348 (E)
(OGPAD)
1-15
(OGPAD)
1-15
AFPD
CHAPTER 4
Page 623
Revision 3.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents