FUNCTION
ICRL
Release timing for incoming trunk connections.
0= 288 msec.
2= 288 msec.
4= 416 msec.
6= 544 msec.
8= 672 msec.
10= 800 msec.
32
12= 928 msec.
14= 1056 msec.
HD
Trunk Hold Timing.
0= 10 sec.
2= 4 sec.
4= 8 sec.
33
6= 12 sec.
8= 16 sec.
10= 20 sec.
12= 24 sec.
14= 28 sec.
GUARD
Ground Timer
Outgoing inhibit timing after trunk release.
0= 3072 msec.
2= 1024 msec.
4= 2048 msec.
34
6= 3072 msec.
8= 4096 msec.
10= 5120 msec.
12= 6144 msec.
14= 7168 msec.
WINK
Width of a Wink Signal
0= 160 msec.
2= 96 msec.
4= 160 msec.
35
6= 224 msec.
8= 288 msec.
10= 352 msec.
12= 416 msec.
14= 480 msec.
36
VAD
37
CLD
Note
1= 224 msec.
3= 352 msec.
5= 480 msec.
7= 608 msec.
9= 736 msec.
11= 864 msec.
13= 992 msec.
15= 1120 msec.
1= 2 sec.
3= 6 sec.
5= 10 sec.
7= 14 sec.
9= 18 sec.
11= 22 sec.
13= 26 sec.
15= 30 sec.
1= 512 msec.
3= 1536 msec.
5= 2560 msec.
7= 3584 msec.
9= 4608 msec.
11= 5632 msec.
13= 6656 msec.
15= 7680 msec.
1= 64 msec.
3= 128 msec.
5= 192 msec.
7= 265 msec.
9= 320 msec.
11= 384 msec.
13= 448 msec.
15= 512 msec.
ND-70348 (E)
RT
Normally assign
data "0".
For ISDN, see Ta-
ble 4-21
407)
Route Class Set-
tings).
Note:
Normally assign data "0".
Normally assign
data "0".
For ISDN, see Ta-
ble 4-21
407)
Route Class Set-
tings).
Normally assign data "0".
0
0
0
0
Always assign data "0".
0
0
0
0
Always assign data "0"
ARTD
REMARKS
(page
(Example of
160 msec. in
case of Loop
Dialing
Trunk.
(page
(Example of
CHAPTER 4
Page 398
Revision 3.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents