NEC NEAX 7400 IMX Command Manual page 96

Table of Contents

Advertisement

SYSTEM
SYSTEM
DATA
DATA
INDEX
TYPE (SYS)
(INDEX)
0 – 511
16
1
17
BIT
DATA
CORRESPONDING
(DATA)
DATA
00 – FF
DATA
(Hex)
BIT
0/1
b
0
b
1
b
2
b
3
b
4
b
5
b
0
6
b
0
7
b
0
b
1
b
2
b
3
b
4
b
0
5
b
6
b
7
ND-70348 (E)
SYSTEM DATA CONTENTS
1-digit Station Number
0/1 = Out/In Service
2-digit Station Number
0/1 = Out/In Service
3-digit Station Number
0/1 = Out/In Service
4-digit Station Number
0/1 = Out/In Service
5-digit Station Number
0/1 = Out/In Service
6-digit Station Number
0/1 = Out/In Service (Hotel system only)
Not used
This bit (data "1") allows single line stations to switch hook
flash and dial an access code while hearing RBT, to place a
voice call to a or activate the D
0/1 = Out/In Service
This bit (data "1") designates that EROW calls can be placed
via the Voice Button of a D
0/1 = Out/In Service
Privacy Release Service for D
0/1 = Out/In Service
This bit (data "1") activates Privacy Release Warning Tone.
0/1 = Not Send/Send
Blind Transfer to Attendant 0/1 = Out/In Service
Not used
Line Privacy Expansion service
0/1 = Out/In Service
Note:
Effective when b
2
Bridge Call 0/1 = Privacy/Non-Privacy Operation
term
's Message Reminder Key.
term
.
term
= 1