Afcd: Assignment Of Fixed Connection-Nailed Down Connection-Data - NEC NEAX 7400 IMX Command Manual

Table of Contents

Advertisement

AFCD: Assignment of Fixed Connection-Nailed Down Connection-Data

1. General
This command is used to assign (connect link), delete (release link), and display the data (linked LENS) per-
taining to Fixed Connections (Nailed Down Connections).
2. Precautions
1.
The Nailed Down connection available among the following circuit cards/terminals.
Single Line station
term
D
Trunk
Conference Trunk
Digital Signaling Trunk
MODEM Trunk
Data Module
Netfusing Call Control Handler (FCH/FGH)
2.
The status of the link is supervised periodically by the system. If the link is not in a "Nailed Down Con-
nection", the link will be forcibly released and reconnected.
3.
The port specified by the LENS-A parameter and LENS-B parameter are "Nailed Down", with respect to
the EAD-A parameter and EAD-B parameter.
4.
The EAD-A parameter and EAD-B parameter should be entered by the hexadecimal value as explained in
Table 4-19.
KIND OF
BIT No.
TERMINAL
TRUNK
b
0
b
1
b
2
b
3
b
-b
4
LINE
b
0
b
1
b
2
b
3
b
-b
4
Note 1:
When DTI is used for Data Communication, Pad Data must be "7" (binary 111).
Note 2:
When bit stealing (signaling bit) is used in DTI, signaling bit (CD RS bit) is lost.
0/1 = -/To inhibit stealing bit (signaling bit) per channel in DTI
(Line circuit)
(ELC)
(DTI, etc.)
(CFT)
(DST)
(MDMT)
(DTL)
Table 4-19 Data for EAD-A/EAD-B
PAD CONTROL
b
b
b
2
1
0
0
0
0
: by dip sw
0
0
1
: 2 dB
0
1
0
: 4 dB
0
1
1
: 11/12 dB
0/1:
Note 2
Not used
7
0/1:Reverse OFF/ON
0/1:PAD OFF/ON
Not used
7