NEC NEAX 7400 IMX Command Manual page 590

Table of Contents

Advertisement

4. Data Sheet
a.) When MODE = TELN is selected:
CDN
1
USPEED
User Speed [0-31]
Assign the User Rate, based on the LLC (Low Layer
Compatibility) information element (TTC Q931) within
the range from 0-31
2
TLC
Test circuit card Exist/Not exist [0/1]
0 = Non Exist
1 = Use Hot Line
3
HL
Hot Line Recognized [0/1]
0 = -
1 = Use Hot Line
4
IRA
Intermediate Rate, based on the LLC (Low Layer Com-
patibility) information element.
0 = Not Assigned
1 = 8 Kbps
2 = 16 Kbps
3 = 32 Kbps
5
ALM
Alarm
0 = -
1 = Alarm
6
139MTC
No Answer Individual Timer overriding SYS1,
INDEX139 of ASYD Miscellaneous Timer Class [0-15]
139MTC × 139TC
7
139TC
No Answer Individual Timer overriding SYS1,
INDEX139 of ASYD Miscellaneous Timer Class [0-7]
139MTC × 139TC
8
140MTC
No Answer Individual Timer overriding SYS1,
INDEX140 of ASYD Miscellaneous Timer Class [0-15]
140MTC × 140TC
9
140TC
No Answer Individual Timer overriding SYS1,
INDEX140 of ASYD Miscellaneous Timer Class [0-7]
140MTC × 140TC
10
141MTC
No Answer Individual Timer overriding SYS1,
INDEX141 of ASYD Miscellaneous Timer Class [0-15]
141MTC × 141TC
11
141TC
No Answer Individual Timer overriding SYS1,
INDEX141 of ASYD Miscellaneous Timer Class [0-7]
141MTC × 141TC
12
247MTC
No Answer Individual Timer overriding SYS1,
INDEX247 of ASYD Miscellaneous Timer Class [0-15]
247MTC × 247TC
13
247TC
No Answer Individual Timer overriding SYS1,
INDEX247 of ASYD Miscellaneous Timer Class [0-7]
247MTC ×247TC
The existing data can be readout by pressing "Get" button after UGN and TELN is entered. If the data
Note:
doesn't exist, input the data and then press "Set" button.
User Group Number (UGN)
Telephone Number (TELN) Max. 16 digits
Fusion Point Code (FPC) 1-253
Tenant Number (TN)
Station Number (STN) Max. 6 digits
ND-70348 (E)
MODE
ADAI_T
TELN
CHAPTER 4
Page 571
Revision 3.0

Hide quick links:

Advertisement

Table of Contents
loading