ATCR: Assignment of Telephone Class Restriction

1. General
This command is used to assign and display the restriction data for connections between Telephone Equipment
Classes (TECs).
2. Precautions
1.
This command is used for the Hotel Application only.
2.
Connection between TECs will be allowed for each RSC until they are restricted by this command.
3.
TEC 31 is used for ATT in this command.
3. Data Entry Instructions
Calling Telephone Equipment Class
1 : DP (10pps)
3 : DP/PB
5 : DP (10pps) : Guest
7 : DP/PB : Guest
9 : House Phone
11 : Not Used
13 : Data Terminal via D
15 : CAS Line
17 : Not Used
19-22 : Not Used
24-25 : Not Used
27 : Eight Conference Equipment
28-30 : Not Used
CALLING
TELEPHONE
EQUIP. CLASS
(CALLING TEC)
1-31
Called Telephone Equipment Class
1 : DP (10pps)
3 : DP/PB
5 : DP (10pps) : Guest
7 : DP/PB : Guest
9 : House Phone
11 : Not Used
13 : Data Terminal via D
15 : CAS Line
17 : Not Used
19-22 : Not Used
24-25 : Not Used
27 : Eight Conference Equipment
28-30 : Not Used
CALLING TEC
2 : PB
4 : DP (20pps)
6 : PS : Guest
8 : DP (20pps) : Guest
10 : House Phone : Guest
term
12 : D
term
14 : Hot Line
16 : Data Terminal via Data Module
18 : Virtual Line Appearance(for D
23 : ISDN Terminal
26 : Not Used
31 : ATT
CALLED
DAY/NIGHT
TELEPHONE
MODE
EQUIP. CLASS
(D/N)
(CALLED TEC)
1-31
CALLED TEC
2 : PB
4 : DP (20pps)
6 : PS : Guest
8 : DP (20pps) : Guest
10 : House Phone : Guest
term
12 : D
term
14 : Hot Line
16 : Data Terminal via Data Module
18 : Virtual Line Appearance(for D
23 : ISDN Terminal
26 : Not Used
31 : ATT
term
Multi-Line)
RESTRICTION
(RES)
D/N
0/1
term
Multi-Line)
ND-70348 (E)
RES
0 : Restricted
1 : Connection is allowed
D/N
D : Day Mode
N : Night Mode
CHAPTER 4