Suzuki Ignis Service Manual page 3597

Rg413
Table of Contents

Advertisement

6H-10 CHARGING SYSTEM
2
6
3
Battery Dismounting and Remounting
Dismounting
1
5
4
Handling
When handling battery, following safety precautions should be
followed:
Remounting
(a)
Generator belt Inspection and Adjustment
For removal, installation, inspection and adjustment referring to
"Water Pump/Generator Drive Belt Tension Inspection and
Adjustment" in Section 6B.
1) Disconnect negative cable (1).
2) Disconnect positive cable (2).
3) Remove retainer (3).
4) Remove battery (4).
5. Body ground bolt
6. Retainer bolt
• Hydrogen gas is produced by battery. A flame or spark near
battery may cause the gas to ignite.
• Battery fluid is highly acidic. Avoid spilling on clothing or
other fabric. Any spilled electrolyte should be flushed with
large quantity of water and cleaned immediately.
1) Reverse removal procedure.
2) Torque battery cables to specification.
NOTE:
Check to be sure that ground cable has enough clear-
ance to hood panel by terminal.
Tightening torque
Body ground bolt (a): 8.0 N·m (0.8 kg-m, 6.0 lb-ft)

Advertisement